8-5
The Characteristics page, shown below, has selections for response
characteristics and phase wrapping.
The following choices are available:
Response Characteristics:
- Specify settling time tolerance — You can set the threshold of the settling
time calculation to any percentage from 0 to 100%. The default is 2%.
- Specify rise time boundaries — The standard definition of rise time is the
time it takes the signal to go from 10% to 90% of the final value. You can
choose any percentages you like (from 0% to 100%), provided that the first
value is smaller than the second.
Phase Wrapping — By default, the phase is not wrapped. Wrap the phrase
by unchecking this box. If the phase is wrapped, all phase values are shifted
such that their equivalent value displays in the range [-180°, 180°).
Parameters Page
Note Click on the page tabs below to get help on LTI Viewer Preference
editor pages.