rltool
11-188
model (sys) in the forward loop of a negative unity feedback system, as shown
in the diagram below.
In this case,
F and H are taken to be 1, while P is sys. If you want to include F
and H in the design model after loading rltool(sys) or rltool(sys,comp),
select the
Import Model menu item from the File menu of the Root Locus
Design GUI to load
F and H.
rltool(sys,comp,LocationFlag,FeedbackSign) allows you to override the
default compensator location and feedback sign.
LocationFlag ca n b e e ither 1
or 2:
LocationFlag = 1: Places the comp ensator in the forward path (this is the
default)
LocationFlag = 2: Places the compensator in the feedback path
FeedbackSign can be either 1 or -1:
-
FeedbackSign = —1 for negative feedback (this is the default)
-
FeedbackSign = 1 for positive feedback
See Also rlocus Plot root locus
rlocfind Select gain from the root locus plot
sys
comp
+_
y
u
Vue de la page 577